(1) Solenoid thermostat mainly consists of a pneumatic connecting union, a Thermostat Body Assy, a Seat Assy, a stick and a Solenoid Assy.
电磁恒温器主要由气动连接接头、恒温器本体组件、阀座组件、阀杆和电磁阀组件组成。
– The pneumatic union has thread characteristics and a dry-lubrication protection treatment that permit full tightening with no risk of seizing.
气动接头具有螺纹特性和干润滑保护处理,可以完全拧紧,没有咬死的风险。
– The thermostat body is made of stainless steel to withstand temperature variations. The mounting tapped hole of the Seat Assy has fine threads to permit a fine adjustment.
恒温器主体由不锈钢制成,可承受温度变化。 阀座组件的安装螺孔带有细螺纹,可进行微调。
– The Seat Assy has an adjusting screw secured into Thermostat Body Assy. A seat equipped with a seal and a stop moves within the bore of the adjusting screw. A spring maintains the seat into contact with the upper end of the stick rod.
– A mesh at the top of the Seat Assy protects the inside of the thermostat against foreign bodies. A castellated nut permits the locking of the adjusting screw.
阀座组件顶部的网罩可保护恒温器内部不受异物影响。 带螺纹的螺母可以锁紧调节螺钉。
– The Solenoid Assy has a body fitted with a spacer that support an electrical connector. A coil installed in the solenoid body accommodates a core. The coil is mechanically maintained into position in the body to withstand vibrations.
(1) Solenoid thermostat continuously senses the temperature of the air delivered downstream the Precooler Heat Exchanger of the bleed air system and monitors the differential pressure between the upstream side of the Bleed Pressure Regulating Valve and the downstream side of the precooler. It limits the air delivery through the bleed air system by controlling the closing of the Bleed Pressure Regulating Valve pneumatically.
(1) The Solenoid thermostat has the following functions: the overheat function and the electrical closing function
电磁恒温器具有以下功能:过热功能和电气关闭功能
(a) Overheat Function (Refer to Figure 3).
过热功能
If the temperature of the air delivery rises to a predetermined level, the tube of stick expands and causes the invar rod to move. The invar rod, which acts as a clapper causes the Bleed Pressure Regulating Valve coupling line to leak. This leak causes the Bleed Pressure Regulating Valve to regulate a lower pressure.
(b) Electrical Closing Function (Refer to Figure 3).
电气关闭功能
When the coil of the Solenoid Assy is energized through the electrical connector, the core moves up. The clapper under the spring load moves off its seat.This permits the venting of the coupling line and causes the closing of the Bleed Pressure Regulating Valve.
This sub-system includes a bleed pressure regulating valve designated bleed valve associated with a bleed valve control solenoid.
该子系统包括一个与引气活门控制电磁铁相关联的引气压力调节活门,称为引气活门。
This sub-system enables the aircraft systems to be supplied with air under a normal nominal pressure lower than or equal to 48 psig (cruise normal flow). The IP stage bleed air pressure (or HP stage pressure if the HP bleed valve fails in the open position) is limited downstream of the bleed valve.
该子系统使飞机系统能够在正常额定压力低于或等于 48 psig(巡航正常流量)的情况下获得空气供应。 IP 级引气压力(或 HP 级压力,如果 HP 引气活门在打开位置发生故障)受限于引气活门下游。
The bleed valve operates pneumatically in relation with the associated bleed valve control solenoid. The bleed valve control solenoid is connected to the bleed valve by a pneumatic sense line and is installed in the duct downstream of the precooler exchanger. The bleed valve control solenoid controls the bleed valve closure when the valve solenoid is energized by the BMC or by action on the ENG BLEED pushbutton switch or ENG FIRE. The bleed valve control solenoid reduces the bleed valve regulated pressure when the temperature exceeds 235⁰C.In case of overpressure caused by the bleed valve failure, the overpressure valve closes.
引气活门与相关的引气活门控制电磁铁气动操作。 引气活门控制电磁阀通过气动感应管路与引气活门连接,并安装在预冷却器交换器下游的管道中。 当 BMC 或 ENG BLEED 按钮开关或 ENG FIRE 给引气活门电磁铁通电时,引气活门控制电磁铁控制引气活门关闭。 当温度超过 235⁰C 时,引气活门控制电磁阀降低引气活门的调节压力。
Bleed valve control solenoid
引气活门控制电磁阀
(a) Operation
工作
The bleed valve control solenoid ensures the following functions:
引气活门控制电磁铁可确保以下功能:
① Pressure limitation slaving (downstream of the bleed valve) to:
压力限制从属(引气活门下游)至:
– the air temperature at the precooler exchanger outlet if the downstream temperature is higher than 235⁰C.This is achieved by decreasing of pressure signal sent to the bleed valve regulator which causes reduction of the bleed valve regulation setting.
② Bleed valve closure.This is achieved by venting the pressure signal sent from the bleed valve regulator by electrical action on the solenoid in case of: